Hazardous Area LCD Display


Class1

Class 1 areas contain the presence of flammable gases or liquid vapors
Please choose from the following Divisions of Class 1 protection:

Class 2

Class 2 areas contain the presence of ignitable metal, carbon or organic dusts
Please choose from the following Divisions of Class 2 protection:

Division 1
Groups B,C,D

Div 1 - area where explosive or flammable materials usually exist under normal conditions

Class1, Div1

Division 2
Groups A,B,C,D

Div 2 - area where explosive or flammable material may exist in abnormal conditions

Class1, Div2

Division 1
Groups E,F,G

Div 1 - area in which ignitable materials usually exist under normal conditions

Class2, Div1

Division 2
Groups E,F,G

Div 2 - areas in which ignitable material may exist under abnormal conditions

Class2, Div2

Hazardous Area LCD Displays

 

VarTech's rugged purged series of industrial LCD displays allow for the placement of totally enclosed monitors into hazloc areas classified as hazardous (explosive or flammable). Intrinsically safe, this purging (pressurization) approach ensures that there will always be a continuous clean air-flow out of the enclosure thereby preventing the intrusion of explosive gasses or dust into the enclosure. These hazardous area LCDs will not cause conditions that may result in an unstable environment.

VarTech offers full NEMA 4X LCDs with hazloc protection classifications:

1. Class 1, Division 1, Groups C, D, and optional B

These LCD displays are equipped with purge systems which insure intrinsic safety in areas where flammable or explosive gasses or vapors are very likely to exists in the air during normal operating conditions. Groups C and D use an automatic purge while Group B requires a standard purge system.

Sizes Supported:17.0" | 19.0"

 

2. Class 1, Division 2, Groups A, B, C, D

These LCD displays are equipped with purge systems which insure intrinsic safety in areas where explosive or flammable gasses or vapors could possibly exist in the air during an abnormal occurance such as a leak.

Sizes Supported: 17.0" | 19.0"

 

3. Class 2, Division 1, Groups E, F, and G

These LCD displays are equipped with purge systems which insure intrinsic safety in areas where ignitable dust, carbon, or ignitable material is very likely to exists in the air during normal operating conditions.

Sizes Supported: 17.0" | 19.0"

 

4. Class 2, Division 2, Groups E, F, and G

These LCD displays are equipped with purge systems which insure intrinsic safety in areas where ignitable dust, carbon, or ignitable material possibly could exist in the air during an abnormal occurance such as a spill.

Sizes Supported: 17.0" | 19.0"

 