MH
Series (MH500S)
500 Watt Single Output Power Supply
|
Features
|
500 watt switching 100 KHz power supply.
|
High efficiency, 65% minimum.
|
Standard soft-start, overvoltage protection
and short circuit protection.
|
| |
Click
here for datasheet (PDF)
|
Specifications
|
Input:
|
103.5-126.5 Vac, 47-440 Hz, single
phase. For 207-253 Vac input, add "(230)" at the end
of the model number.
|
Efficiency:
|
65% minimum.
|
Line Regulation:
|
25 mV or withing 0.2%, whichever
is greater, for input change of 103.5 to 126.5 Vac with load constant.
|
Load Regulation:
|
25 mV or 0.2%, whichever is greater
for change from no load to full load with line constant.
|
Pard (Noise and Ripple):
|
50 mV rms, 100 mV P-P maximum at 25 MHz bandwidth.
|
Isolation Voltage:
|
500 Vdc, input to output; 500 Vdc,
input to case; 100 Vdc, output to case.
|
Insulation Resistance:
|
50 Mohms between input and output,
input and case, output and case, when measured at 50 Vdc.
|
Polarity:
|
Inputs and outputs are isolated.
Either positive or negative side of output may be grounded.
|
Temperature Range:
|
Operating: 0°C to +71°C maximum,
at center of the mounting. Storage: -55°C to +85°C, ambient.
|
Temperature Coefficient:
|
0.03% / °C maximum over entire temp range.
|
Input Transient Protection:
|
Unit will provide normal regulated
output and withstand 180 Vac for 0.1 second, in accordance with
MIL-STD-704A.
|
Load Transient Recovery:
|
Output voltage returns to regulation
limits within 300 microseconds after 50% change in load current.
|
Holdup time:
|
20ms after nominal input is lost at full load.
|
Short Circuit Protection:
|
Completely protected against a short
circuit of any duration. Output automatically restores to normal
when overload is removed.
|
Overvoltage Protection:
|
A non-crowbar type OVP. Input must
be recycled to restore output.
|
Remote Sensing:
|
Regulator monitors voltage directly
at the load using extra "sensing" leads and compensates
for a dc voltage drop up to .3 volt in the load leads.
|
EMI:
|
Units were designed and tested to
the requirement of MIL-STD-461B, Class A1B, for generation of and
susceptibility to radiated and conducted interference. For further
details and reports, consult your nearest sales office.
|
Reliability:
|
MTBF is calculated per MIL-HDBK-217D
at 50°C baseplate temperature with maximum operating input voltage
and maximum rated output power. The MTBF for MH500S at ground benign
environment is 54,530 hours.
|
Environment:
|
Encapsulated and hermetically sealed
to meet the environmental requirements of MIL-STD-810C, MIL-S-901C,
and MIL-E-5400P, Class 2, including altitude (to 70,000 feet),
vibration, shock, acceleration, sand, dust, humidity, saltspray,
fungus, explosion, etc.
|
Connectors:
|
Standard unit is provided with an
input solder pin header and an output "hermetic seal" stud-type
connector.
|
Single
Output
|
|
Output Voltage Range
|
Output Current (Amps)
|
Weight (oz.)
|
Size (inches)
|
MH500S/5-DE
|
4.75-5.25
|
100
|
15
|
7 x 10 x 3.5
|
MH500S/12-DE
|
11.40-12.60
|
41.67
|
15
|
7 x 10 x 3.5
|
MH500S/15-DE
|
14.25-15.75
|
33.33
|
15
|
7 x 10 x 3.5
|
MH500S/24-DE
|
22.80-25.20
|
20.83
|
15
|
7 x 10 x 3.5
|
MH500S/28-DE
|
26.60-29.40
|
17.86
|
15
|
7 x 10 x 3.5
|
|
Model
Numbering System
|
Model Series
|
Total Output Power
|
Number of Outputs
|
|
Main Output Voltage
|
|
Header Type
|
|
Encapsulation (Standard)
|
|
Options
|
MH
|
500
|
S
|
/
|
12
|
-
|
D
|
-
|
E
|
-
|
R
|
Options
|
A Option:
|
Special Connectors. A military-type
hermetically sealed connector is provided in place of our standard
input header. To order, replace the "D" in the model
with "A".
|
H Option:
|
Wide Input Voltage. Unites will
operate either from 115 Vac±15%. To order, add an "H" after
the "E" in the model number.
|
L Option:
|
Remote Turn On/Off. Provides isolated
terminals to turn output on/off with TTL logic signal. To order,
add "L" after "E" in the model number.
|
R Option:
|
Remote Output Adjustment. An adjustment
potentiometer can be remotely located to adjust the output voltage.
To order, add "R" after "E" in the model number.
|
T Option:
|
Wider Operating Temperature. -20°C
to +71°C. To order, add "T" after "E" in the
model number.
|
-ER Option:
|
Provides increased reliability by
using higher levels of military grade components.
|
-3 Option:
|
WYE Input. Changes input to 3-phase,
4-wire "WYE". To order, add "-3" to the end
of the model number.
|
-6 Option:
|
Three Phase Delta Input. Changes
input to 3-Phase Delta. To order, add "-6" to the end
of the model number.
|
-8 Option:
|
Variable Input. Allows input to
be either 115 Vac or 230 Vac, selectable by input pin wiring, 47
- 440 Hz. To order, add "-8" to the end of the model
number.
|
|