M Series
(M300S/M300T)
300 Watt Single & Triple Output Power Supply
|
Features
|
300 watt single & triple output switching
power supply.
|
High efficiency, 60% minimum.
|
Meets MIL-STD-461B, MIL-STD-810C and MIL-S-901C.
|
| |
Click here
for datasheet (PDF)
|
Specifications
|
Input:
|
103.5-126.5 Vac, 47-440 Hz, single
phase. Other inputs available (H and -3 options.)
|
Efficiency:
|
60% minimum at full load.
|
Line Regulation:
|
25 mV or within 0.2%, whichever
is greater, for change from low line to high line with load constant.
|
Load Regulation:
|
25 mV or 0.2%, whichever is greater
for change from no load to full load with line constant.
|
Auxiliary Output Tracking:
|
The negative output will track the
positive output within 200 mV for all rated conditions (M300T).
|
Pard (Noise and Ripple):
|
Main and Auxiliary outputs: 30 mV
rms, 100 mV P-P maximum at 25 MHz bandwidth, over entire temperature
range.
|
Isolation Voltage:
|
500 Vdc, input to output; 500 Vdc,
input to case; 100 Vdc, output to case.
|
Insulation Resistance:
|
50 Mohms between input and output,
input and case, output and case, when measured at 50 Vdc.
|
Temperature Range:
|
Operating: 0°C to +71°C maximum,
at center of the baseplate. Storage: -55°C to +85°C, ambient.
|
Temperature Coefficient:
|
0.01% / °C for main and auxiliary
outputs over entire temp range.
|
Input Transient Protection:
|
Unit will withstand 143.8 Vac for
0.3 second, in accordance with MIL-STD-1399.
|
Load Transient Recovery:
|
Output voltage returns to regulation
limits within 1.5 milliseconds for main and 100 microseccond for
auxiliary outputs after 50% change in load current.
|
Holdup time:
|
10ms after nominal input is lost at full load.
|
Short Circuit Protection:
|
Completely protected against a short
circuit of any duration. Output automatically restores to normal
when overload is removed.
|
Current Limiting:
|
Output current is limited to 120%
on main and auxiliary outputs (±10%) under overload conditions.
|
Remote Sensing:
|
Regulator monitors voltage directly
at the load using extra "sensing" leads and compensates
for a dc voltage drop up to .5 volt in the load leads.
|
EMI:
|
Units were designed and tested to
the requirement of MIL-STD-461B, Class A1B, for generation of and
susceptibility to radiated and conducted interference. For further
details and reports, consult your nearest sales office.
|
Reliability:
|
MTBF is calculated per MIL-HDBK-217D
at 50°C baseplate temperature with maximum operating input voltage
and maximum rated output power. The MTBF for M300T at ground benign
environment is 77,455 hours.
|
Environment:
|
Encapsulated and hermetically sealed
to meet the environmental requirements of MIL-STD-810C and MIL-S-901C,
Class 2, including altitude (to 70,000 feet), vibration, shock,
acceleration, sand, dust, humidity, saltspray, fungus, explosion,
etc.
|
Connectors:
|
Standard unit is provided with an
input solder pin header and an output "hermetic seal" stud-type
connector.
|
|
Single
Output
|
|
Output Voltage Range
|
Output Current (Amps)
|
Weight
(Lbs.)
|
Size (inches)
|
A
|
B
|
C
|
M300S/5-D
|
4.75-5.25
|
60.0
|
7.8
|
6 x 8 x 3
|
M300S/12-D
|
11.40-12.60
|
25.0
|
7.8
|
6 x
8 x 3
|
M300S/15-D
|
14.25-15.75
|
20.0
|
7.8
|
6 x
8 x 3
|
M300S/24-D
|
22.80-25.20
|
12.5
|
7.8
|
6 x
8 x 3
|
M300S/28-D
|
26.60-29.40
|
10.7
|
7.8
|
6 x
8 x 3
|
Triple
Output
|
|
Output Voltage (main/aux)
|
Output Current (m/aux)
|
Weight (Lbs.)
|
Size (inches)
|
A
|
B
|
C
|
M300T/5/12-D
|
5 / ±12
|
48/2.5
|
9.2
|
6 x 8 x 3
|
M300T/5/15-D
|
5 / ±15
|
48/2.0
|
9.2
|
6 x
8 x 3
|
Model
Numbering System
|
Model Series
|
Total Output Power
|
# of Outputs
|
|
Main Output Voltage
|
|
Aux. Output Voltage
|
|
Header Type
|
|
Options
|
M
|
300
|
T
|
/
|
5
|
/
|
12
|
-
|
D
|
-
|
R
|
Options
|
A Option:
|
Special Connectors. A military-type
hermetically sealed connector is provided in place of our standard
input header. To order, replace the "D" in the model
with "A".
|
E Option:
|
Severe Shock, Acceleration and Vibration.
Enables all units to withstand 60 g's shock, 50 g's acceleration
and 30g's vibration. To order, add "E" after "D" in
the model number.
|
H Option:
|
Wide Input Voltage. Units will operate
from 90 to 126.5 Vac with 20% derating in output power. To order,
add an "H" after the "D" in the model number.
|
L Option:
|
Remote Turn On/Off. Provides isolated
terminals to turn output on/off with TTL logic signal. To order,
add "L" after "D" in the model number.
|
R Option:
|
Remote Output Adjustment. An adjustment
potentiometer can be remotely located to adjust the output voltage.
To order, add "R" after "D" in the model number.
|
T Option:
|
Wider Operating Temperature. -20°C
to +71°C. Pard (noise and ripple) specification increases to 200
mV P-P. To order, add "T" after "D" in the
model number.
|
-ER Option:
|
Provides increased reliability by
using higher levels of military grade components. To order, add "-ER" after
the model number.
|
-3 Option:
|
WYE Input. Changes input to 3-phase,
4-wire "WYE". To order, add "-3" to the end
of the model number.
|
-7 Option:
|
50/50 Power Split. Provides a 50/50
power split between main and auxiliary outputs (50% main output,
25% each,, auxiliary outputs). Load regulation of auxiliary outputs
will be 2 times greater than standard model. To order, add "-7" to
the end of the model number.
|
|